================================= Restarting a simulation ================================= The restart functionality of ComFLOW can be used to restart a simulation, for example after a system failure or power breakdown. It can also be used ''by design" to restart a simulation with modified simulation settings. One could for example start a simulation with large Poisson tolerance ``linear_solver/stopping_criterion/outer_p`` (see :numref:`linear_solver/stopping_criterion`) for faster spin-up of the simulation and then continue with a smaller value for increased accuracy. Similarly one could start-up a simulation with a large time step and then continue with a smaller one by reducing the CFL tolerance (see :numref:`Chapter %s `). It is possible to apply a restart with almost any change of simulation settings as long as it does not concern the domain and grid setup or type of simulation (e.g. one or two-phase). As a general rule, one should be careful with changing simulation settings after a restart. The time step size as well as the end time of the simulation can be changed. The time interval for post-processing output (snapshots, monitor points, etc.) is identical to that of the original simulation unless the attribute ``@reset_counters~`` is set to ``"true"``. The ComFLOW program includes the possibility to save your simulation and restart it at a later time. Special snapshot files including additional information about the simulation status can be written at a specified time interval. The settings related to the restart functionality are included in the XML section ``/comflow/restart/``. The following parameters can be specified: * ``@tmin``, ``@tmax``, ``@dt``, ``@nr``: Output interval using the notation as explained in :numref:`xml_documentation/time_intervals`. * ``@reset_counters``: If this parameter is set to ``"true"`` all the counters for post-processing output are reset upon restart, otherwise counting just continues where ComFLOW left off. Upon restart ComFLOW reinterprets the main input file(s) hence it is possible to restart a simulation with modified settings (e.g. a different convection scheme or a different CFL limit). .. note:: Be careful when changing simulation settings after a restart. Some settings such as the simulation type (e.g. one-phase/two-phase, with/without moving bodies, etc.) *cannot* be changed afterwards. ------------------------------- Example ------------------------------- The following code can be used to produce restart files at a given interval: .. code-block:: xml The restart files will be stored at the locations ``${OUTPUT}/restart/autosave####.save``, where ``####`` is replaced by the file counter. It is recommended to copy or move important restart files to a new location outside the subdirectory ``restart`` since this will prevent it from being overwritten by subsequent simulations. To restart a simulation use the command-line option ``--restart RESTART`` where ``RESTART`` has to be replaced by the location of the desired restart file. For more details, see :numref:`Chapter %s `. It is possible to restart the simulation with a modified input file. The option ``restart/@reset_counters`` causes the output intervals and counters of restart files and other post-processing output to be reset to the values specified in the *new* input file. Compare the following input section with that of the original input file listed above: .. code-block:: xml .. .. rubric:: Footnotes .. .. rubric:: References .. .. bibliography:: references.bib